Test Code Phos Plas or Phos Ser Phosphorus, Plasma or Serum
Performing Laboratory
NRL-Chemistry
Methodology
Photometric End point
Note: This test is also available as part of #RENAL Renal Function Panel. See Common Panel Test Combinations in Special Instructions to avoid duplicate test requests when multiple panels are ordered.
Specimen Requirements
Submit only 1 of the following specimens:
Preferred:
Specimen Type: Plasma
Container/Tube: Light-green top (lithium heparin)
Specimen Volume: 2 mL
Specimen Minimum Volume: 1 mL
Collection Instructions:
1. Spin down unopened (vacuum intact) tube within 45 minutes of draw.
2. Avoid hemolysis.
3. Label specimen as plasma.
Alternate (Non-Hospital Patient):
Specimen Type: Serum
Container/Tube: Gold top, serum gel
Specimen Volume: 2 mL
Specimen Minimum Volume: 1 mL
Collection Instructions:
1. Spin down unopened (vacuum intact) tube within 45 minutes of draw.
2. Avoid hemolysis.
3. Label specimen as serum.
Specimen Transport Temperature
Refrigerate
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
STAT-45 minutes
Routine-shift
Reference Values
0-30 days: 4.2-7.2 mg/dL
31 days-17 years: 3.3-6.3 mg/dL
≥18 years: 2.7-4.7 mg/dL
Test Classification and CPT Coding
84100