Test Code Urinalysis, Macro only Urinalysis, Macroscopic (Dipstick)
Performing Laboratory
NRL-Urinalysis
Methodology
Includes color, turbidity, specific gravity, pH, protein, glucose, ketones, bile, blood, urobilinogen, nitrites, and leukocyte esterase.
Specimen Requirements
Specimen Type
- Urine
Collection container
- Sterile urine cup
- Urine collection kit (proper name)
Specimen Volume
- Minimum of 10mL
Specimen Requirements
- Collection method is required. Clean catch or catheter are preferred.
Catheter
- Clean catheter with an alcohol sponge, puncture with a sterile needle, and collect in sterile syringe. Do not collect urine from drainage bag.
Clean Catch
Female
- Wash hands thoroughly with soap and water. Dry with a clean paper towel.
- Unscrew the lid of the urine cup without touching the inside of the cup.
- Place the lid on a clean surface with the inside facing up.
- Spread the labia (folds of skin around the urinary opening) using your non-dominant hand.
- Use the first wipe to clean the area between the labia. Discard the wipe.
- Use a new wipe to clean the center over the urinary opening. Discard each wipe after use.
- Stand or squat over the toilet. Start urinating into the toilet to discard the first portion of urine.
- Without stopping the urine stream, bring the sterile cup into the stream and collect urine until the cup is about half full. Avoid touching the inside of the cup or lid.
- Complete urination into the toilet or commode.
- Tightly screw the lid onto the cup. Wash your hands again.
- Give the urine cup to the healthcare staff or place it in the designated collection area.
- Ensure patient’s name (first and last), date and actual time of collection, and source of specimen is on the specimen label.
Male
- Wash hands thoroughly with soap and water. Dry with a clean paper towel.
- Unscrew the lid of the urine cup without touching the inside of the cup.
- Place the lid on a clean surface with the inside facing up.
- If not circumcised, hold foreskin back before cleansing.
- Wipe head of penis in a single motion with first wipe.
- Repeat with second wipe.
- Stand or squat over the toilet. Start urinating into the toilet to discard the first portion of urine.
- Without stopping the urine stream, bring the sterile cup into the stream and collect urine until the cup is about half full. Avoid touching the inside of the cup or lid.
- Complete urination into the toilet or commode.
- Tightly screw the lid onto the cup. Wash your hands again.
- Give the urine cup to the healthcare staff or place it in the designated collection area.
- Ensure patient’s name (first and last), date and actual time of collection, and source of specimen is on the specimen label.
Specimen Transport Temperature
Refrigerate
Specimen Stability
- 2 hours at room temperature
- 4 hours refrigerated
- 72 hours in urine preservative
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
2 hour
Reference Values
Specific gravity: 1.001-1.033
pH: 5.0-8.0
Protein: negative
Glucose: negative
Ketones: negative
Bile: negative
Blood: negative
Urobilinogen: 0.2 mg/dL
Leukocyte esterase: negative
Nitrites: negative
Test Classification and CPT Coding
81003