Test Code LDL Direct LDL (Low-Density Lipoprotein), Direct Measurement, Plasma or Serum
Performing Laboratory
NRL-Chemistry
Methodology
Timed End point
Note: This test is also available as part of #LIPID Lipid Panel or #LIPIDR Lipid Panel, Reflex to Direct LDL. See Common Panel Test Combinations in Special Instructions to avoid duplicate test requests when multiple panels are ordered.
Specimen Requirements
Submit only 1 of the following specimens:
Preferred:
Specimen Type: Plasma
Container/Tube: Light-green top (lithium heparin)
Specimen Volume: 1 mL
Specimen Minimum Volume: 0.5 mL
Collection Instructions:
1. Fasting (12-14 hours)
2. Patient must not consume any alcohol for 24 hours before specimen is drawn.
3. Spin down unopened (vacuum intact) tube within 45 minutes of draw.
4. Avoid hemolysis.
5. Label specimen as plasma.
Alternate (Non-Hospital Patient):
Specimen Type: Serum
Container/Tube: Gold top, serum gel
Specimen Volume: 1 mL
Specimen Minimum Volume: 0.5 mL
Collection Instructions:
1. Fasting (12-14 hours)
2. Patient must not consume any alcohol for 24 hours before specimen is drawn.
3. Spin down unopened (vacuum intact) tube within 45 minutes of draw.
4. Avoid hemolysis.
5. Label specimen as serum.
Reference Values
0-19 years: 50-109 mg/dL
>19 years: 60-129 mg/dL
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
Routine-shift
Specimen Transport Temperature
Refrigerate
Test Classification and CPT Coding
83721